Data Center HVAC - Cooling systems cfd

Data Center HVAC - Cooling systems cfd

The Engineering Mindset

6 лет назад

360,776 Просмотров

Ссылки и html тэги не поддерживаются


Комментарии:

Matt
Matt - 13.05.2023 04:02

Great video! I don't know if I am the first to nerd out on this video and pick it apart like a troll, but you incorrectly call a computer room cooling unit (@10m:44s) connected to chilled water system a CRAC but its actual a CRAU (Computer Room Air Handling Unit). There is no AC (Air Conditioning) when using a chiller so I get it and using the term "Crack" is a generalization. If I am building a project and we have chilled or condenser water in the computer room I start to worry about a new set of issues, computer and water don't mix.

Ответить
Think And Question
Think And Question - 13.04.2023 06:13

Great information. Thank you

Ответить
Jason Richardsone
Jason Richardsone - 31.01.2023 14:48

One work exceptional - thank you

Ответить
HN C
HN C - 27.09.2022 18:35

why there are gas pipes for the outdoor unit of a water-cooled in-row unit?

Ответить
Talon Williams
Talon Williams - 24.07.2022 21:56

Your content is so touching

Ответить
Ward Wixon
Ward Wixon - 06.07.2022 16:52

Nicely explained-

Ответить
akshay korlekar
akshay korlekar - 21.04.2022 15:27

Thanks

Ответить
CjMc
CjMc - 24.03.2022 18:33

You are too fast in explanation, otherwise it is good !

Ответить
Innocent Nwachukwu
Innocent Nwachukwu - 14.03.2022 09:58

This is an awesome video. Thank you so much for putting this together. It is very helpful.

Ответить
Wilberth Enrique
Wilberth Enrique - 15.01.2022 16:12

Thank you Paul!

Ответить
Asem Ahmed
Asem Ahmed - 07.11.2021 22:44

I hope you put an Arabic language as translation

Ответить
OthmanEmpire
OthmanEmpire - 01.11.2021 18:04

Thanks for the video =)

Ответить
Asif Hussain
Asif Hussain - 18.10.2021 09:36

Sir, you are explaining in much easier way but can you please explain what is basic of data center after that this critical one

Ответить
Ask real question by ZK
Ask real question by ZK - 14.08.2021 06:50

Can you please help us to understand the effect of unfiltered or generated gases due to heat..what are the effects and how can we tackle the issue..

Ответить
Jakov Bilić
Jakov Bilić - 22.07.2021 21:00

Wow, great work!!

Ответить
Ajay Kumar
Ajay Kumar - 16.07.2021 09:09

Dear sir please. Make a video all in hindi ....

Ответить
so8 up8
so8 up8 - 29.05.2021 19:09

what the best hvac system design for data center

Ответить
richard wager
richard wager - 10.03.2021 23:49

Would be good to see a video on static transfer switches 👍🏻

Ответить
Samuel Frondozo Jr.
Samuel Frondozo Jr. - 04.03.2021 10:23

You have good application of Air conditioning systemapplied to all type of Area of location in a residential or commercial building.

Ответить
Артем Чахоян
Артем Чахоян - 02.03.2021 19:46

👍👍👍

Ответить
Brent Williams
Brent Williams - 05.02.2021 07:50

I find it funny that HVAC is for Aircons, where its been a very long Time the means of "High Voltage Alternating Current".

Ответить
Sorose Kaewmanee
Sorose Kaewmanee - 16.01.2021 07:49

Very good video

Ответить
Mark Arca
Mark Arca - 28.12.2020 15:08

This is also called CRAC (Computer Room Airconditioning) units.

Ответить
g g
g g - 14.12.2020 04:36

All of these are junk. I run several crappy black pipes 7ft under ground for 200ft and pump in 48F air into my greenhouse and room year around. Can't get more efficient than 1 fan.

Ответить
𝕷1𝖓𝖚𝖘
𝕷1𝖓𝖚𝖘 - 03.12.2020 14:21

Why cant I see the VRF video? It's not available does it say..

Ответить
Mirul Arif
Mirul Arif - 24.10.2020 14:57

Hey, im currently working on my assignment data center. Does anyone know how to select diffuser for floor raised.

Ответить
E Cantil
E Cantil - 22.10.2020 06:20

With regards to the DC Energy Consumption ratio: I think its best to allocate 50% of power on HVAC and 36% on IT Equipment (10% on Network Devices and 26% on Server and Storage).

Ответить
Apokalypz
Apokalypz - 15.10.2020 15:45

Side note, if the CRAC unit is using chilled water then it's typically called a CRAH (computer room air handling) unit. This is due to not having the compressor or majority of the work to cool being actually IN the unit like it is with a CRAC unit. With CRAH's the compressor doing the most work is typically in the upstream chiller or heat rejection equipment of similar type and function.

Ответить
Exterminator
Exterminator - 19.09.2020 18:10

What you described as a 'CRAC' unit is actually a 'CRAH' unit.

Ответить
Dr.Andy Hill
Dr.Andy Hill - 15.09.2020 01:17

This video is particularly applicable to me.
Modern HPC clusters often have power consumption in the MW range and often uses liquid cooling for CPUs GPUs and RAM, these usually consist of a local liquid loop with a heat exchanger linked to a secondary loop fed from the building chilled water system.

Ответить
Philip Mungai
Philip Mungai - 26.08.2020 10:59

Nice video

Ответить
Kasim Shaikh
Kasim Shaikh - 04.08.2020 08:05

I work at JLL in facilities management your videos are really helpful.

Ответить
George Cicairos
George Cicairos - 10.06.2020 09:00

Data centers are always expanding, they often don't take into consideration the added heat load. They just keep pushing in more racks. One solution was a manifold piping system over head, with quick connects. You just place fan unit cooler on top of the new data rack and hook up the quick connect flexible refrigeration lines that's it. The main cooling unit has a large reservoir to accommodate multiple fan units. It was years ago when I helped install the manifold piping system, and I can't remember what it was called. Maybe someone knows the system name.

Ответить
Hosh Wagan
Hosh Wagan - 02.06.2020 11:08

I found it realy helpful.

Ответить
S H
S H - 01.06.2020 13:41

Can you provide me ppt presentation for like this without voice for 2 different topics?

Ответить
Ryan Ellinger
Ryan Ellinger - 01.06.2020 08:13

This is a cool video, but I work for a big commercial refrigeration and HVAC company in Arizona. I have never seen this. We do all the work for Century link in Arizona. They only use chillers or rtus. I’m not saying this doesn’t happen, but I think with all the bad airflow just use a chiller with multiple air handlers. Thanks for the video.

Ответить
Nilesh Gaikwad
Nilesh Gaikwad - 15.05.2020 05:25

Please make video on immersion cooling data center technology.

Ответить
Carlo San Pedro
Carlo San Pedro - 28.04.2020 08:47

I'd like to know how fire suppression nozzle will be placed if there will be a ductwork for hot aisle containtment system?

Ответить
Ajithkumar Sarathy
Ajithkumar Sarathy - 23.04.2020 20:13

Can you explain about relative humidity. Why it is important in precision AC and data center

Ответить
Kimberly Sulit
Kimberly Sulit - 09.04.2020 23:19

This is helpful for my architectural thesis, thanks.

Ответить
Ahmad Surkanicks
Ahmad Surkanicks - 16.03.2020 17:03

I just knew the hot isle containment.. 👍👍

Ответить
__
__ - 15.02.2020 21:28

May you share the Simscale design? :D

Ответить
--
-- - 22.01.2020 06:41

versatemp in a data centre, not very efficient

Ответить
Connor Watson
Connor Watson - 11.12.2019 21:18

What are the sources for this video so I can do more research?

Ответить
mustafa ahmed
mustafa ahmed - 25.11.2019 23:40

can i get HAP file for these room ?

Ответить
David Summergreene
David Summergreene - 10.05.2019 13:20

I do this everyday this video is spot on great job you deserve my thumbs up

Ответить
VVS
VVS - 30.04.2019 12:21

Hey Paul, the VRF video is missing. Can you upload this one again?

Ответить