Комментарии:
Great video! I don't know if I am the first to nerd out on this video and pick it apart like a troll, but you incorrectly call a computer room cooling unit (@10m:44s) connected to chilled water system a CRAC but its actual a CRAU (Computer Room Air Handling Unit). There is no AC (Air Conditioning) when using a chiller so I get it and using the term "Crack" is a generalization. If I am building a project and we have chilled or condenser water in the computer room I start to worry about a new set of issues, computer and water don't mix.
ОтветитьGreat information. Thank you
ОтветитьOne work exceptional - thank you
Ответитьwhy there are gas pipes for the outdoor unit of a water-cooled in-row unit?
ОтветитьYour content is so touching
ОтветитьNicely explained-
ОтветитьThanks
ОтветитьYou are too fast in explanation, otherwise it is good !
ОтветитьThis is an awesome video. Thank you so much for putting this together. It is very helpful.
ОтветитьThank you Paul!
ОтветитьI hope you put an Arabic language as translation
ОтветитьThanks for the video =)
ОтветитьSir, you are explaining in much easier way but can you please explain what is basic of data center after that this critical one
ОтветитьCan you please help us to understand the effect of unfiltered or generated gases due to heat..what are the effects and how can we tackle the issue..
ОтветитьWow, great work!!
ОтветитьDear sir please. Make a video all in hindi ....
Ответитьwhat the best hvac system design for data center
ОтветитьWould be good to see a video on static transfer switches 👍🏻
ОтветитьYou have good application of Air conditioning systemapplied to all type of Area of location in a residential or commercial building.
Ответить👍👍👍
ОтветитьI find it funny that HVAC is for Aircons, where its been a very long Time the means of "High Voltage Alternating Current".
ОтветитьVery good video
ОтветитьThis is also called CRAC (Computer Room Airconditioning) units.
ОтветитьAll of these are junk. I run several crappy black pipes 7ft under ground for 200ft and pump in 48F air into my greenhouse and room year around. Can't get more efficient than 1 fan.
ОтветитьWhy cant I see the VRF video? It's not available does it say..
ОтветитьHey, im currently working on my assignment data center. Does anyone know how to select diffuser for floor raised.
ОтветитьWith regards to the DC Energy Consumption ratio: I think its best to allocate 50% of power on HVAC and 36% on IT Equipment (10% on Network Devices and 26% on Server and Storage).
ОтветитьSide note, if the CRAC unit is using chilled water then it's typically called a CRAH (computer room air handling) unit. This is due to not having the compressor or majority of the work to cool being actually IN the unit like it is with a CRAC unit. With CRAH's the compressor doing the most work is typically in the upstream chiller or heat rejection equipment of similar type and function.
ОтветитьWhat you described as a 'CRAC' unit is actually a 'CRAH' unit.
ОтветитьThis video is particularly applicable to me.
Modern HPC clusters often have power consumption in the MW range and often uses liquid cooling for CPUs GPUs and RAM, these usually consist of a local liquid loop with a heat exchanger linked to a secondary loop fed from the building chilled water system.
Nice video
ОтветитьI work at JLL in facilities management your videos are really helpful.
ОтветитьData centers are always expanding, they often don't take into consideration the added heat load. They just keep pushing in more racks. One solution was a manifold piping system over head, with quick connects. You just place fan unit cooler on top of the new data rack and hook up the quick connect flexible refrigeration lines that's it. The main cooling unit has a large reservoir to accommodate multiple fan units. It was years ago when I helped install the manifold piping system, and I can't remember what it was called. Maybe someone knows the system name.
ОтветитьI found it realy helpful.
ОтветитьCan you provide me ppt presentation for like this without voice for 2 different topics?
ОтветитьThis is a cool video, but I work for a big commercial refrigeration and HVAC company in Arizona. I have never seen this. We do all the work for Century link in Arizona. They only use chillers or rtus. I’m not saying this doesn’t happen, but I think with all the bad airflow just use a chiller with multiple air handlers. Thanks for the video.
ОтветитьPlease make video on immersion cooling data center technology.
ОтветитьI'd like to know how fire suppression nozzle will be placed if there will be a ductwork for hot aisle containtment system?
ОтветитьCan you explain about relative humidity. Why it is important in precision AC and data center
ОтветитьThis is helpful for my architectural thesis, thanks.
ОтветитьI just knew the hot isle containment.. 👍👍
ОтветитьMay you share the Simscale design? :D
Ответитьversatemp in a data centre, not very efficient
ОтветитьWhat are the sources for this video so I can do more research?
Ответитьcan i get HAP file for these room ?
ОтветитьI do this everyday this video is spot on great job you deserve my thumbs up
ОтветитьHey Paul, the VRF video is missing. Can you upload this one again?
Ответить