vPC configuration Nexus 5000/2000

vPC configuration Nexus 5000/2000

Cisco Community

1 десятилетие назад

59,237 Просмотров

Ссылки и html тэги не поддерживаются


Комментарии:

Ken Cheng
Ken Cheng - 31.01.2018 06:12

good content, bad video quality

Ответить
Merrill Weathermay
Merrill Weathermay - 02.01.2018 18:38

Excellent video. The only thing I would add is how VDC ties into this

Ответить
Jack Pomidor
Jack Pomidor - 13.04.2017 10:55

Hey - what happens if I go to my N5k-1 and do a configuration change on a FEX port, say I changed configs on Eth117/1/1. Would this change be reflected if I go to to my N5k-2 and do a "show run int Eth117/1/1" ?

Ответить
Cinemagrphy
Cinemagrphy - 07.04.2017 18:32

awesome job

Ответить
Khan
Khan - 26.02.2017 15:48

excellent demonstration

Ответить
Gipper
Gipper - 18.11.2015 18:55

Excellent! Thanks!

Ответить
Jafer Sabir
Jafer Sabir - 07.12.2013 22:14

Very productive and to the point :)

Ответить
kmunson007
kmunson007 - 14.10.2013 08:24

Thanks! Super good video - just enough info!

Ответить
Olives&Sweets
Olives&Sweets - 09.10.2013 17:53

Thank You! very well explained!

Ответить
dumbterminal1981
dumbterminal1981 - 20.08.2013 00:33

Thanks so much...

Ответить
DJStickyFusion
DJStickyFusion - 22.05.2013 03:46

Disregard last comment, i forgot to put "vrf management" after the ping command... DOH!! Please help to respond my other previous comments if you can though.

Ответить
DJStickyFusion
DJStickyFusion - 22.05.2013 03:45

I tried setting this up with a crossover between the 2 mgmt0 NICs on the back of my N5Ks. I set them with the ip addresses of 10.0.0.1 and 10.0.0.2 with a 24 bit mask. They cannot PING each other. Says no route to host. What could be going on?

Ответить
DJStickyFusion
DJStickyFusion - 21.05.2013 23:59

And further, would I need to carve out a couple of ports for port-channel on each 5K for management since I would be using the MGMT0 interface for the keep-alive?

Ответить
DJStickyFusion
DJStickyFusion - 21.05.2013 23:58

Can you shed a bit of light on this for me? I just received 2 N5Ks and 2 Nexus 2248 2248TP-E FEX devices. I have the layer 3 module for the 5K as this will be our new Core. I want some redundancy and I realize the 5K doesn't have full redundancy because of the single supervisor. My question is this... would I connect them in the proper way like this: Connect MGMT0 on back of each 5K to each other for the keep alive you mention in this video? And then connect each FEX to both 5K for failover?

Ответить
BALA CHANDHAR
BALA CHANDHAR - 23.02.2013 02:21

Nice... Thanks

Ответить
Shoaib Gul
Shoaib Gul - 09.02.2013 20:09

Very Informative !!! Demonstrated In A Very Simple & Easy Way !!

Ответить
Michael Samoska
Michael Samoska - 19.01.2013 06:26

nice demo

Ответить
sakabio
sakabio - 16.01.2013 13:56

Very helpful as i am going on a job and never configured this before

Ответить
Vikram Patani
Vikram Patani - 19.10.2012 22:15

Great Video

Ответить