How to calculate the over-lapping length of steel bars in slab,column and beam

How to calculate the over-lapping length of steel bars in slab,column and beam

Civil Engineers

7 лет назад

188,563 Просмотров

Ссылки и html тэги не поддерживаются


Комментарии:

Famil Abdullayev
Famil Abdullayev - 31.03.2023 09:51

Hindistanlının da qadasın alım Pakistanlinin da

Ответить
Rasmil Alih Tuttuh
Rasmil Alih Tuttuh - 27.04.2022 20:40

Hai Sami!

Ответить
Qasim Awan Vlogs
Qasim Awan Vlogs - 09.02.2022 19:00

Very good

Ответить
Ali Shah
Ali Shah - 30.12.2021 08:42

What is 40D ??

Ответить
Moiz Salah
Moiz Salah - 28.09.2021 22:26

Really u are a civil engineer??

Ответить
Abdul Sattar
Abdul Sattar - 02.09.2021 11:52

L4 Kiya hai aur ye Kahan istmal HOTA hai

Ответить
Ashish Shegokar
Ashish Shegokar - 25.08.2021 20:52

Good bro...🇮🇳🇮🇳

Ответить
Ashish Shegokar
Ashish Shegokar - 25.08.2021 20:52

A r u pakistani.

Ответить
Best Regards
Best Regards - 04.03.2021 17:18

lala i m your student for ever. Great Job 👍👍👍

Ответить
karthick km
karthick km - 06.10.2020 13:28

Column 50D?

Ответить
Akhil kumar Nelapatla
Akhil kumar Nelapatla - 07.09.2020 17:21

This is not cleared sir please explain the full video...

Ответить
A B
A B - 27.06.2020 19:32

very much half infoed video

Ответить
PASHTOON AESTHETIC
PASHTOON AESTHETIC - 23.04.2020 14:25

which standard?

Ответить
vimal nath
vimal nath - 20.09.2019 08:08

sir can plz tell why should not provide a torsional reinforcement in two way slab ......can u plz explain in site detailing

Ответить
Shafqat & Co.
Shafqat & Co. - 03.07.2019 19:57

oh bhai jan ya 40 khan sa aya is ko b describe karan phr pata chal;a formula ka

Ответить
akshay gote
akshay gote - 17.06.2019 08:56

Nice

Ответить
ABRAR ULLAH
ABRAR ULLAH - 13.06.2019 09:12

If in a structure, e.g, 20mm steel bar is not available and
we use 12mm steel bar instead of 16mm bar, how can we
calculate the no. of steel bars for 16mm diameter bar? what space will be enough pls

Ответить
Ed
Ed - 01.05.2019 10:16

Hi i have a column in my garage i want to extend it but theres no rebar to overlap it what is the best thing to do .

Ответить
umair ahmed
umair ahmed - 21.11.2018 09:54

Is It constant that beam overlapping is 40d and column overlapping is 24d????.

Ответить
muhammad mukhtar
muhammad mukhtar - 28.10.2018 15:09

Dear I want to build 3 story building may column size is 6x12 inch with 12mm 6 steel bar . Is this safe .

Ответить
Ramen Paul
Ramen Paul - 12.06.2018 06:05

Colum,Beem & slab par very interesting deferent calculations hay, for the subject to lapping.
My Question is -
Ham kiu welding nehi kartey ?
Keya IS / BBS code allow nehi kartey for the welding of bar

Namaskar.
*Any body reply allowable.

Ответить
MR. aEz
MR. aEz - 04.04.2018 19:28

25 mm steel

Ответить
Uma Kant
Uma Kant - 22.03.2018 19:57

Kitne percent overlap IS standard ke according use ki ja sakti hai slab me

Ответить
Abinash Rout
Abinash Rout - 11.02.2018 13:40

hey you can't say for beam it is 40D and for column it is 24D cz it depends upon the grade of concrete you use like suppose if you are using m50 grade in column then lapping length will be 36D

Ответить
Ziaf Hashmi
Ziaf Hashmi - 17.01.2018 20:29

Sir how to identify the rebar like grade 60,40 etc.

Ответить
Mohd Anas
Mohd Anas - 05.01.2018 12:54

Wrong

Ответить
tanzeel qureshi
tanzeel qureshi - 02.01.2018 15:46

sir plz send me link of profiling and designing in road structure plz plz for using Autocad

Ответить
narendra sewag
narendra sewag - 27.11.2017 09:22

How to calculate lap distance Ld....plz upload video

Ответить
Sunny TV HD
Sunny TV HD - 24.11.2017 00:49

give ur nmbr or whatsapp nmbr i want ask about overlaping plzz

Ответить
Kiran Kumar
Kiran Kumar - 19.11.2017 13:36

24 mm kadhu 25 ,d 40 kadhu d50 iam a radbening warkar

Ответить
Jabir Hayan
Jabir Hayan - 04.11.2017 19:56

Sir plz make video of extra top bar and botom bar for slab and beam!!

Ответить
muvvala lavakumar
muvvala lavakumar - 28.10.2017 19:06

actually the lapping length is calculated by usinf the formula ((0.87fy)÷(4×tbd))×dia of bar??

Ответить
Mahfooz Ilahi
Mahfooz Ilahi - 19.10.2017 12:41

can you upload a video about the test of concrete in field ..?

Ответить
Henry .Pham.VietNam
Henry .Pham.VietNam - 10.10.2017 05:43

Thank you very much for your video

Ответить
Jessie Inu
Jessie Inu - 24.07.2017 18:03

Follow a code: ACI, BS, IS, etc to know your minimum overlaps if you are not sure.

Ответить
Sivasankar
Sivasankar - 22.07.2017 17:54

Am working as a TA in TNPHC and here we using 50D for overlapping

Ответить
Juan Rogelio Lugo
Juan Rogelio Lugo - 30.05.2017 10:40

thank you for this video sir, it really helped me

Ответить
Mohammad Irshad
Mohammad Irshad - 16.05.2017 20:24

thid is not standard it may be 40D or 50D

Ответить
Esafa SMS
Esafa SMS - 13.05.2017 11:00

what is 12 mm and what is 40D explain me sir

Ответить
Brock Lesnar
Brock Lesnar - 07.05.2017 12:50

sir if we use different steel diameter in element than now which diameter should be taken the small or the larger one?

Ответить
saleem khan
saleem khan - 04.05.2017 22:24

Sir what about foundation where we have length greater than 12 meter we go for overlapping. please arrange lecture for it .

Ответить
Ankur Verma
Ankur Verma - 29.04.2017 12:49

why you take 25mm in column overlapping

Ответить
RIYAZ SHAH
RIYAZ SHAH - 27.04.2017 12:22

sir app Hindi video make

Ответить
Mark Lacipo
Mark Lacipo - 20.04.2017 08:53

For column they usually we multiply by 60 D

Ответить
Mark Lacipo
Mark Lacipo - 20.04.2017 06:48

Thank you very much

Ответить
bandi anilkumar
bandi anilkumar - 13.04.2017 19:24

how to calculate the manpower

Ответить