How to test 3-phase motor using MEGGER meter ? Winding resistance and insulation test.

How to test 3-phase motor using MEGGER meter ? Winding resistance and insulation test.

266,068 Просмотров

Ссылки и html тэги не поддерживаются


Комментарии:

chnbrs
chnbrs - 12.07.2023 22:08

So should we connect the plus end of the megger to the body or to the winding? so how should the correct polarity be?

Ответить
Patrick Lulama
Patrick Lulama - 12.07.2023 14:03

Excellent ❤

Ответить
Innocent Mutanga
Innocent Mutanga - 16.03.2023 17:55

Thankx

Ответить
papa Kutty
papa Kutty - 27.02.2023 18:46

Please explain with audio this is not useful.. can't understand for freshers

Ответить
falgun patel
falgun patel - 16.02.2023 19:20

Apart from this tests which one is insulation resistance (IR) test?

Ответить
Saul Reyes
Saul Reyes - 10.11.2022 19:53

Where are the equivalents to 7,8 & 9 leads?? What kind of sorcery is this?

Ответить
Mike Adler
Mike Adler - 24.04.2022 21:57

👍👍

Ответить
garbo
garbo - 31.03.2022 01:22

Taking too much time. Out in the real world the production boss demands quick but accurate troubleshooting. I was an industrial electrician for 50 great years and NEVER removed jumpers on an POS IEC motor or wasted time measuring resistance from IEC motor coil to another. If a winding is shorted or grounded does not matter because motor must be replaced ASAP. Ran several 480 motors with 5 meggerohms from motor coil to ground. You placed one merger lead on a painted surface . A big no no . Must be clipped to ground screw or bare clean metal. Should tell people that merger voltage is supposed to be double the line voltage plus a hundred volts so you need a 1,000 volt merger to properly measure a 480 volt motor. I own a nice 5,000 volt merger that found grounds in several 4,160 volt motors over the years.

Ответить
Bolt Automation
Bolt Automation - 19.05.2021 03:52

It is unnecessary to remove the star connection when doing insulation resistance test.

Ответить
Ahmedyaasiin Hassanuur
Ahmedyaasiin Hassanuur - 01.05.2021 02:18

Simplify about the motor

Ответить
Juan carlos Galvan
Juan carlos Galvan - 06.04.2021 23:26

Very good👍👍👍

Ответить
Yuba Chuck
Yuba Chuck - 21.01.2021 14:09

Firstly: What is the allowable value of the insulation resistance? Secondly: You must reverse the connections of your device, the positive terminal will be connected on the winding and the negative terminal on the the motor housing. Good luck!

Ответить
W D
W D - 07.01.2021 18:06

Should have shown a bad one.

Ответить
I K
I K - 23.08.2020 17:42

Sir motor windings are connected in star or delta ? Bcoz there's no strip.

Ответить