Stirrup is more than 6 mm there. Im sure
ОтветитьIt depends on the roof also... May be its a dyna roof with not so much weight just like rcc slab which required bigger rod
ОтветитьLap
Ответитьmy mistri didnot give any development length in corners
hwo fucked am I already one plinth beam is done but other sides are left
I want the plinth beam to have vertical offset at different locations... If I explain it further, usually complete plinth beam is at same elevation... But i want my plinth beam at some portion of home at different elevation... My floor level for whole house would be same... But the location where the elevation is low, I will use dpc at floor level... Can you answer that is this mandatory to make plinth level at same elevation or want is the reason for this, if so?
Ответитьاگر یہ ب** اردو میں ہوتی تو زیادہ بہتر تھا
Ответить👍🏾👍🏾👍🏾👍🏾
ОтветитьHindi please
ОтветитьChoto
Gph0
wheir u make this video i m work in dubai stell superviser ten year i did not see like this beam what u share in chinal
Ответить30 inch what u mean
ОтветитьStirupps looks like 8mm 🤔🙃
ОтветитьSir i am from occupied kashmir
Can i have your whats app number
Its urgnt
Steel looks like 6mm
ОтветитьA very big mistake by you was the measurement of Centre to centre of stirrups. You should measure it from the centre of a stirrup bar to the centre of next stirrup bar. But instead you measured from end to end.
ОтветитьFifth mistake. Stirrups hook in 135 degree not provide.
Ответитьپاگل انسان اردو میں تو بکواس کرو۔۔
ОтветитьSir we can use 12mm 4 main bar and 16mm 2 bar in 3 floors building
ОтветитьWhat place is this?
ОтветитьWhy providing side reinforcement.... it’s unnecessary unless beam depth is more than 750 mm
ОтветитьTell you hindi
ОтветитьNormal se pun la 15 cm ,nu la 30.
ОтветитьNu se vad etrieri la noduri.
ОтветитьSo why the factory produce smaller steel beam if we can not use them?
ОтветитьIs crank bar is required for plinth beam
ОтветитьSir if the dia of the bottom beam is 10mm then can we provide extra bottom????
ОтветитьHello, can you suggest a book about this kind of topics?
Ответитьstirupps looks like 8 incha dia
ОтветитьIt's bull shit. Plinth fails due to tensile stress. How come they provided 3 rods vertically and only 2 rod horizontally? It should be the other way around.
ОтветитьFine guidance...
Ответитьit should 135 degrees for the hook include it to ur evaluation
ОтветитьGood
ОтветитьJAZAKALLAH
ОтветитьVery nice sir
Ответитьبھائی صاحب is 456 2000 کا پاکستانی انجینئر سے کیا تعلق آپ اُن کوڈ سے بتایا کریں نا جو پاکستان میں فالو کیے جاتے ہیں جیسے astm،ubc،etc اور پاکستانی بلڈنگ کوڈ building code of pakistan
ОтветитьGood
ОтветитьStirrups seems to be fine ......it doesn't look less than 6mm
ОтветитьBUT.. DOESN'T IT ALL DEPEND ON How many floors the building will be
Ответитьjiii... what's the 3rd mistake.... couldn't understand, that's why asking... kindly reply.
ОтветитьI didn't quite understand the the third mistake concerning beam and column.
Ответитьgentleman it is not a common mistake.
This is not designed by a structural engineer. It is done by a worker .
so you cannot expect more from this
Improve your Grammer
ОтветитьI think the Reif at bottom shall not be less than 12mmm not 20mm.the steel shall be as per design.
ОтветитьWhat about spacing neer column is it L4?
ОтветитьSir what about hook length of stirrups sir I hope hook should be 135°
ОтветитьBrother mashwara yeh hai ke ap urdu may video banaya krein taa k sab ko samajh ajaye
Ответитьthere is no clearance under bottom bars for concrete. creates a void around bottom bars. forms should be in place.
ОтветитьThey were trying to save money and hoped the owners would not notice
ОтветитьSir we follow ACI codes nt IS
Ответить