4 Big and Common Mistakes in Plinth Beam - Common Mistakes in beam

4 Big and Common Mistakes in Plinth Beam - Common Mistakes in beam

Civil Engineers

4 года назад

307,293 Просмотров

Ссылки и html тэги не поддерживаются


Комментарии:

@glsganesh5271
@glsganesh5271 - 15.12.2023 09:24

Stirrup is more than 6 mm there. Im sure

Ответить
@Guiding100
@Guiding100 - 09.07.2023 16:08

It depends on the roof also... May be its a dyna roof with not so much weight just like rcc slab which required bigger rod

Ответить
@civilenginner6075
@civilenginner6075 - 31.05.2022 18:51

Lap

Ответить
@vvvRASvvv
@vvvRASvvv - 13.02.2022 20:24

my mistri didnot give any development length in corners
hwo fucked am I already one plinth beam is done but other sides are left

Ответить
@mutiur7396
@mutiur7396 - 27.01.2022 16:36

I want the plinth beam to have vertical offset at different locations... If I explain it further, usually complete plinth beam is at same elevation... But i want my plinth beam at some portion of home at different elevation... My floor level for whole house would be same... But the location where the elevation is low, I will use dpc at floor level... Can you answer that is this mandatory to make plinth level at same elevation or want is the reason for this, if so?

Ответить
@iftikharsyed9801
@iftikharsyed9801 - 26.12.2021 07:33

اگر یہ ب** اردو میں ہوتی تو زیادہ بہتر تھا

Ответить
@L145channel.
@L145channel. - 13.09.2021 14:31

👍🏾👍🏾👍🏾👍🏾

Ответить
@zakierhussian8459
@zakierhussian8459 - 08.08.2021 14:59

Hindi please

Ответить
@kousiksau160
@kousiksau160 - 01.08.2021 16:45

Choto
Gph0

Ответить
@sayedswat9696
@sayedswat9696 - 23.07.2021 12:51

wheir u make this video i m work in dubai stell superviser ten year i did not see like this beam what u share in chinal

Ответить
@sayedswat9696
@sayedswat9696 - 23.07.2021 12:48

30 inch what u mean

Ответить
@raeesfaizu3866
@raeesfaizu3866 - 24.06.2021 10:21

Stirupps looks like 8mm 🤔🙃

Ответить
@aleeilhaan2077
@aleeilhaan2077 - 18.06.2021 12:31

Sir i am from occupied kashmir
Can i have your whats app number
Its urgnt

Ответить
@girishkamble9618
@girishkamble9618 - 15.06.2021 17:54

Steel looks like 6mm

Ответить
@anujbarman9506
@anujbarman9506 - 05.06.2021 09:03

A very big mistake by you was the measurement of Centre to centre of stirrups. You should measure it from the centre of a stirrup bar to the centre of next stirrup bar. But instead you measured from end to end.

Ответить
@gunaseelangunaseelan1745
@gunaseelangunaseelan1745 - 11.04.2021 07:43

Fifth mistake. Stirrups hook in 135 degree not provide.

Ответить
@ibrahimgorgage4120
@ibrahimgorgage4120 - 30.03.2021 05:02

پاگل انسان اردو میں تو بکواس کرو۔۔

Ответить
@PrashantSharma-rr6se
@PrashantSharma-rr6se - 08.03.2021 11:59

Sir we can use 12mm 4 main bar and 16mm 2 bar in 3 floors building

Ответить
@araavila309
@araavila309 - 18.02.2021 07:30

What place is this?

Ответить
@naruash2227
@naruash2227 - 28.01.2021 18:03

Why providing side reinforcement.... it’s unnecessary unless beam depth is more than 750 mm

Ответить
@sryoutube5909
@sryoutube5909 - 16.01.2021 06:03

Tell you hindi

Ответить
@viosog9661
@viosog9661 - 14.01.2021 17:27

Normal se pun la 15 cm ,nu la 30.

Ответить
@viosog9661
@viosog9661 - 14.01.2021 17:25

Nu se vad etrieri la noduri.

Ответить
@kimjongun6229
@kimjongun6229 - 14.01.2021 16:54

So why the factory produce smaller steel beam if we can not use them?

Ответить
@pradyotsaha2579
@pradyotsaha2579 - 22.11.2020 20:02

Is crank bar is required for plinth beam

Ответить
@inamkhan9437
@inamkhan9437 - 30.10.2020 01:39

Sir if the dia of the bottom beam is 10mm then can we provide extra bottom????

Ответить
@tazodavitadze5535
@tazodavitadze5535 - 12.10.2020 01:47

Hello, can you suggest a book about this kind of topics?

Ответить
@jayjoshi6379
@jayjoshi6379 - 25.09.2020 07:19

stirupps looks like 8 incha dia

Ответить
@pravesssh1751
@pravesssh1751 - 17.09.2020 02:58

It's bull shit. Plinth fails due to tensile stress. How come they provided 3 rods vertically and only 2 rod horizontally? It should be the other way around.

Ответить
@steevensonkhandagale8395
@steevensonkhandagale8395 - 29.08.2020 17:48

Fine guidance...

Ответить
@luto-lutotaguyz8824
@luto-lutotaguyz8824 - 27.08.2020 08:54

it should 135 degrees for the hook include it to ur evaluation

Ответить
@moorthym4669
@moorthym4669 - 06.08.2020 08:04

Good

Ответить
@Engineeringeeks
@Engineeringeeks - 03.08.2020 11:15

JAZAKALLAH

Ответить
@kshitijmishra4330
@kshitijmishra4330 - 26.07.2020 16:34

Very nice sir

Ответить
@kamraniqbal2304
@kamraniqbal2304 - 25.07.2020 12:40

بھائی صاحب is 456 2000 کا پاکستانی انجینئر سے کیا تعلق آپ اُن کوڈ سے بتایا کریں نا جو پاکستان میں فالو کیے جاتے ہیں جیسے astm،ubc،etc اور پاکستانی بلڈنگ کوڈ building code of pakistan

Ответить
@abdirahmanismail6518
@abdirahmanismail6518 - 24.07.2020 08:28

Good

Ответить
@gagancod07
@gagancod07 - 24.07.2020 01:31

Stirrups seems to be fine ......it doesn't look less than 6mm

Ответить
@043ash
@043ash - 14.07.2020 05:57

BUT.. DOESN'T IT ALL DEPEND ON How many floors the building will be

Ответить
@abdulrahmanm6311
@abdulrahmanm6311 - 13.07.2020 11:15

jiii... what's the 3rd mistake.... couldn't understand, that's why asking... kindly reply.

Ответить
@japhethabrahammapis8202
@japhethabrahammapis8202 - 06.07.2020 19:29

I didn't quite understand the the third mistake concerning beam and column.

Ответить
@sasikumartherayil9620
@sasikumartherayil9620 - 02.07.2020 06:16

gentleman it is not a common mistake.
This is not designed by a structural engineer. It is done by a worker .
so you cannot expect more from this

Ответить
@adarshpatel500
@adarshpatel500 - 01.07.2020 11:28

Improve your Grammer

Ответить
@sambasivarao98
@sambasivarao98 - 30.06.2020 10:33

I think the Reif at bottom shall not be less than 12mmm not 20mm.the steel shall be as per design.

Ответить
@rolandogallardo395
@rolandogallardo395 - 27.06.2020 06:03

What about spacing neer column is it L4?

Ответить
@civilengineerkorrasanthosh8628
@civilengineerkorrasanthosh8628 - 19.06.2020 07:30

Sir what about hook length of stirrups sir I hope hook should be 135°

Ответить
@mohammedusman4970
@mohammedusman4970 - 04.06.2020 08:58

Brother mashwara yeh hai ke ap urdu may video banaya krein taa k sab ko samajh ajaye

Ответить
@TheMambomaster
@TheMambomaster - 03.06.2020 05:58

there is no clearance under bottom bars for concrete. creates a void around bottom bars. forms should be in place.

Ответить
@10tenman10
@10tenman10 - 30.05.2020 02:16

They were trying to save money and hoped the owners would not notice

Ответить
@skacademy416
@skacademy416 - 24.05.2020 11:28

Sir we follow ACI codes nt IS

Ответить