TIA Portal: PUT Command / PLC-PLC Communication

TIA Portal: PUT Command / PLC-PLC Communication

Hegamurl

4 года назад

92,375 Просмотров

Ссылки и html тэги не поддерживаются


Комментарии:

@sashkindg
@sashkindg - 06.10.2019 17:58

Hello! With PUT, Data Blocks can be optimized ?

Ответить
@Reaper0931
@Reaper0931 - 29.12.2023 20:18

Hey, How can I send more information ? Im a beginner and you say in the end of the video that it is possible, how ?

Ответить
@mechtronics42
@mechtronics42 - 08.11.2023 18:11

Hi sir! Your tutorial is amazing ❤. I have a question: is it possible to take text input from a human-machine interface and then process it using if/else statements like in programming? For example, the user types "password" and if the password is wrong, you know, like an if/else statement in programming.

Ответить
@jamesedrielleaurellana
@jamesedrielleaurellana - 11.10.2023 03:55

😍😍😍

Ответить
@mirrorcopy4681
@mirrorcopy4681 - 16.09.2023 05:25

மிகவும் நன்றி நண்பா

Ответить
@NikitaBelousovIE
@NikitaBelousovIE - 08.07.2023 20:18

Thank you very much for so easy explanation of the complicated things!

Ответить
@dennisrubio2375
@dennisrubio2375 - 20.06.2023 03:03

why does not PLC 102 isnt on profinet red plz help sr

Ответить
@framos9991
@framos9991 - 13.04.2023 12:30

My favorite teacher /Thank you!

Ответить
@mrloh7197
@mrloh7197 - 07.04.2023 14:34

Is it possible to use Put and Get instruction with the CPUs with different TIA Portal Version? One using V15.1 and another using V16.0.

Ответить
@mobros1298
@mobros1298 - 06.03.2023 02:06

so clear thank you

Ответить
@crja4114
@crja4114 - 04.03.2023 23:34

My good friend you have a new subscriber. Thanks.

Ответить
@user-ch1ep4hi7q
@user-ch1ep4hi7q - 29.01.2023 05:32

I need to get encoder value from another cpu can I use the GET bock
and how???

Ответить
@Raul-jl1nd
@Raul-jl1nd - 22.01.2023 19:35

thanks, grate job

Ответить
@ericanderson560
@ericanderson560 - 18.01.2023 21:41

Do you have to be online for this to work? I can't get it to work at all. It tells me the data type is wrong when it is clearly correct, or it tells me the specified value is invalid

Ответить
@kadadjamel4545
@kadadjamel4545 - 19.12.2022 15:42

MERCI beaucoup

Ответить
@mat77111
@mat77111 - 22.11.2022 21:26

I take it this method doesn’t work with S7-1200 PLCs?

Ответить
@austins.275
@austins.275 - 14.10.2022 08:01

Man I ran out of inputs on a big project and thought "PLC to PLC communication should be easy" 72 hours of pulling my hair and you saved me. Had EVERYTHING right but couldn't get the REQ parameter to work and your video explained it perfects. Thank you!

Ответить
@ouluberlu7373
@ouluberlu7373 - 15.09.2022 19:15

Hi, I'have got a 1214CPU and using TIA V15. Unfortunatley, S7-communication library is missing. Do you know if I can import it in TIA? If yes, where can I get this library?
Or is it a default library?

Thanks for your videos !

Ответить
@BG-gr1uu
@BG-gr1uu - 05.09.2022 17:26

Please improve voice quality,

Ответить
@mohdshahzad9427
@mohdshahzad9427 - 01.09.2022 17:20

How to convert 1 Word into bits via siemens S7 1200 PLC?

Ответить
@ericanderson560
@ericanderson560 - 08.08.2022 05:58

DO you have to set up a TCON to do a put? If not what's the purpose of setting up the TCON in the prior video?

Ответить
@shushimhuntinwabbits
@shushimhuntinwabbits - 07.07.2022 16:42

Once again, a logical clear explanation for anything Siemens based... Thanks so much 🙂

Ответить
@76POK
@76POK - 04.06.2022 22:54

Thanks again. I have got so much help from this site!

Ответить
@naifsahin
@naifsahin - 29.04.2022 19:19

Very useful, thanks.

Ответить
@seanyushi9096
@seanyushi9096 - 09.03.2022 16:36

The connection id is actually not taken care by TIA. I've tried to have more than 1 PUT instructions and all of the block will always have the identical configuration following the latest changes i made, e.g. ip address of partner, memory address, etc. And this might be my issue, i need to change the connection name.

Ответить
@whatacode
@whatacode - 17.12.2021 04:59

How Can we send use put for more than 5 plc and send data to one Common plc.....
Please respond sir

Ответить
@hansbrannstrom620
@hansbrannstrom620 - 26.11.2021 11:56

Hi Thanks a lot for all nice videos you share with us :-)
Is it even possible to test this PUT & GET function with PLC SIM? I does not get it to work....

Ответить
@Automation28
@Automation28 - 12.11.2021 16:21

thanks for your videos, those are very useful to learn about automation

Ответить
@MrPushpalm
@MrPushpalm - 04.11.2021 12:19

Will s71200 communicate with s71500

Ответить
@kreditslavkov8115
@kreditslavkov8115 - 15.10.2021 08:46

Hello, pleace can i have a guestion.... i used a condition as you did at the end of the video for the REQ input. i also put a negativ contact "PUT_DB".DONE instead of freguency. but when i did it for the first time nothing has came into the my next plc. when i deleted it and did it again and upload the plc program again, it works. But when i was working on that again today also same problem and i have to do the same solution. deleted that condition and do it again the same. unfortunetly i cannot used the frueqvency condition, do you know why this negativ contact "PUT_DB".DONE doesnt work for the first time(the datablock put_db is green, but nothing has came into the database on the next plc...)? and is there any solution idea for condition like do it with every cycle of the cpu?

Ответить
@stuatkins5
@stuatkins5 - 09.09.2021 19:53

hi great video , if i wanted to send a qr code value (say PAC123) from one plc to another is a put instruction the best way?

Ответить
@danielesauhs5083
@danielesauhs5083 - 29.05.2021 20:47

Hey man! I really like your videos, your explanations are excepcional, thanks for this knowlegment.
Just a quick question, I have 2 PLC 1500, both have diferent subred, but one of them have two ethernet ports available, is it possible to link each other trought this free port?

Ответить
@HectorRodriguez-si3yr
@HectorRodriguez-si3yr - 08.04.2021 17:42

i love u man, thanks a lot.

Ответить
@sagarparmar8904
@sagarparmar8904 - 07.04.2021 18:57

Sir , your videos are very helpful thanks 🙏

Ответить
@ikkusoft
@ikkusoft - 08.03.2021 10:01

Can this be simulated in PLC SIM,
I tried, I'm not getting value in other PLC.

Ответить
@kathirangamuthu3574
@kathirangamuthu3574 - 19.12.2020 10:49

Thanks

Ответить
@GeneralKiller1337
@GeneralKiller1337 - 03.12.2020 20:28

Nice job, Hega! I have one question: can I use this protocol with SINAMICS devices or the S7 protocol is only for the comunication between 2 S7 PLCs?

Ответить
@alvaropalenciano6147
@alvaropalenciano6147 - 15.11.2020 21:36

Master!

Ответить
@legendary686
@legendary686 - 07.11.2020 01:44

Thanks for the video. I have a question. Can you do this with PLCs from different brands? i.e Sending data from my siemens PLC to an omron in a different project for example?

Ответить
@melvingomez426
@melvingomez426 - 05.11.2020 17:09

How do you send multiple data..🙏🏽

Ответить
@zedjag7701
@zedjag7701 - 22.10.2020 23:45

Another great TIA Portal video, thanks a lot.

Ответить
@Der_Geraet1
@Der_Geraet1 - 25.09.2020 16:57

Kann man damit auch bspw. M0.0 der einen sps setzt M0.0 der zweiten sps? Sprich kann man einfach nur merker 1 und 0 setzten damit?

Ответить
@akshayjadhav6145
@akshayjadhav6145 - 11.08.2020 09:08

Hello, thanks for such great videos.
Could you have a video on Ethernet diagnostics to find communication error in your network and display on HMI.
That would be very helpful
And thank once again

Ответить
@NotMarkKnopfler
@NotMarkKnopfler - 07.08.2020 23:52

Is this command also available over Profibus (rather than Profinet)? Thanks :-)

Ответить
@umairshah9735
@umairshah9735 - 13.07.2020 11:50

Hi dear , Watching your vids . Best one can offer for the betterment of human beings . Thanks alot . Dear i want to send my Level signal from one PLC to other . I am no expert . Kindly, advice me videos in your playlist which can help me . Thanks

Ответить
@vijayakanthm705
@vijayakanthm705 - 15.04.2020 15:04

Thanks to your good work.I have a question That i didn’t have a physical plc ,so shall configure two plc’s in a single project and test them with each other by single PLCSIM.Don’t bother if it is a genuine question

Ответить
@zhengkunyan8001
@zhengkunyan8001 - 20.03.2020 11:03

Good

Ответить
@beautyofislam323
@beautyofislam323 - 20.03.2020 09:58

Thanks sir

Ответить