Комментарии:
Hello! With PUT, Data Blocks can be optimized ?
ОтветитьHey, How can I send more information ? Im a beginner and you say in the end of the video that it is possible, how ?
ОтветитьHi sir! Your tutorial is amazing ❤. I have a question: is it possible to take text input from a human-machine interface and then process it using if/else statements like in programming? For example, the user types "password" and if the password is wrong, you know, like an if/else statement in programming.
Ответить😍😍😍
Ответитьமிகவும் நன்றி நண்பா
ОтветитьThank you very much for so easy explanation of the complicated things!
Ответитьwhy does not PLC 102 isnt on profinet red plz help sr
ОтветитьMy favorite teacher /Thank you!
ОтветитьIs it possible to use Put and Get instruction with the CPUs with different TIA Portal Version? One using V15.1 and another using V16.0.
Ответитьso clear thank you
ОтветитьMy good friend you have a new subscriber. Thanks.
ОтветитьI need to get encoder value from another cpu can I use the GET bock
and how???
thanks, grate job
ОтветитьDo you have to be online for this to work? I can't get it to work at all. It tells me the data type is wrong when it is clearly correct, or it tells me the specified value is invalid
ОтветитьMERCI beaucoup
ОтветитьI take it this method doesn’t work with S7-1200 PLCs?
ОтветитьMan I ran out of inputs on a big project and thought "PLC to PLC communication should be easy" 72 hours of pulling my hair and you saved me. Had EVERYTHING right but couldn't get the REQ parameter to work and your video explained it perfects. Thank you!
ОтветитьHi, I'have got a 1214CPU and using TIA V15. Unfortunatley, S7-communication library is missing. Do you know if I can import it in TIA? If yes, where can I get this library?
Or is it a default library?
Thanks for your videos !
Please improve voice quality,
ОтветитьHow to convert 1 Word into bits via siemens S7 1200 PLC?
ОтветитьDO you have to set up a TCON to do a put? If not what's the purpose of setting up the TCON in the prior video?
ОтветитьOnce again, a logical clear explanation for anything Siemens based... Thanks so much 🙂
ОтветитьThanks again. I have got so much help from this site!
ОтветитьVery useful, thanks.
ОтветитьThe connection id is actually not taken care by TIA. I've tried to have more than 1 PUT instructions and all of the block will always have the identical configuration following the latest changes i made, e.g. ip address of partner, memory address, etc. And this might be my issue, i need to change the connection name.
ОтветитьHow Can we send use put for more than 5 plc and send data to one Common plc.....
Please respond sir
Hi Thanks a lot for all nice videos you share with us :-)
Is it even possible to test this PUT & GET function with PLC SIM? I does not get it to work....
thanks for your videos, those are very useful to learn about automation
ОтветитьWill s71200 communicate with s71500
ОтветитьHello, pleace can i have a guestion.... i used a condition as you did at the end of the video for the REQ input. i also put a negativ contact "PUT_DB".DONE instead of freguency. but when i did it for the first time nothing has came into the my next plc. when i deleted it and did it again and upload the plc program again, it works. But when i was working on that again today also same problem and i have to do the same solution. deleted that condition and do it again the same. unfortunetly i cannot used the frueqvency condition, do you know why this negativ contact "PUT_DB".DONE doesnt work for the first time(the datablock put_db is green, but nothing has came into the database on the next plc...)? and is there any solution idea for condition like do it with every cycle of the cpu?
Ответитьhi great video , if i wanted to send a qr code value (say PAC123) from one plc to another is a put instruction the best way?
ОтветитьHey man! I really like your videos, your explanations are excepcional, thanks for this knowlegment.
Just a quick question, I have 2 PLC 1500, both have diferent subred, but one of them have two ethernet ports available, is it possible to link each other trought this free port?
i love u man, thanks a lot.
ОтветитьSir , your videos are very helpful thanks 🙏
ОтветитьCan this be simulated in PLC SIM,
I tried, I'm not getting value in other PLC.
Thanks
ОтветитьNice job, Hega! I have one question: can I use this protocol with SINAMICS devices or the S7 protocol is only for the comunication between 2 S7 PLCs?
ОтветитьMaster!
ОтветитьThanks for the video. I have a question. Can you do this with PLCs from different brands? i.e Sending data from my siemens PLC to an omron in a different project for example?
ОтветитьHow do you send multiple data..🙏🏽
ОтветитьAnother great TIA Portal video, thanks a lot.
ОтветитьKann man damit auch bspw. M0.0 der einen sps setzt M0.0 der zweiten sps? Sprich kann man einfach nur merker 1 und 0 setzten damit?
ОтветитьHello, thanks for such great videos.
Could you have a video on Ethernet diagnostics to find communication error in your network and display on HMI.
That would be very helpful
And thank once again
Is this command also available over Profibus (rather than Profinet)? Thanks :-)
ОтветитьHi dear , Watching your vids . Best one can offer for the betterment of human beings . Thanks alot . Dear i want to send my Level signal from one PLC to other . I am no expert . Kindly, advice me videos in your playlist which can help me . Thanks
ОтветитьThanks to your good work.I have a question That i didn’t have a physical plc ,so shall configure two plc’s in a single project and test them with each other by single PLCSIM.Don’t bother if it is a genuine question
ОтветитьGood
ОтветитьThanks sir
Ответить