Insulation Resistance Test of Transformer

Insulation Resistance Test of Transformer

The Engineering Power

2 года назад

95,654 Просмотров

Ссылки и html тэги не поддерживаются


Комментарии:

@smartengineeringeee4990
@smartengineeringeee4990 - 13.01.2024 19:12

Please give the reference informations in detail that where did you get it.

Ответить
@chandanjana6964
@chandanjana6964 - 15.11.2023 07:20

Informative, Thnx sir.

Ответить
@benjaminotettey6315
@benjaminotettey6315 - 29.09.2023 08:53

I love the explanation

Ответить
@kdmq
@kdmq - 15.08.2023 06:22

It's OK to say that any transformer is safe to operate at 20 Celsius, but what if the manufacturing company knows that the transformer is going to be subjected to ambient temperatures much hotter than 20 Celsius? Isn't it better to apply the IR test for the maximum operating temperature. For example, if the transformer is being used in hot summer climates where the temperature regularly reaches 35 Celsius, shouldn't we apply the test for 35 Celsius to make sure there will be no arcing at all times of the year?

Ответить
@jasonchristopheraguillon4988
@jasonchristopheraguillon4988 - 03.06.2023 15:37

Insulation Reating of Einding must be not lower Than 10Giga ohms not in mega

Ответить
@TwoFaced2
@TwoFaced2 - 07.03.2023 12:15

Can you please make videos on testing of power cables

Ответить
@86karna
@86karna - 04.02.2023 08:03

How the input supply is injected for testing of transformer?. Input source

Ответить
@Wolf.88
@Wolf.88 - 29.01.2023 21:41

Thanks!

Ответить
@erisherm.8451
@erisherm.8451 - 02.01.2023 01:47

Very informative indeed 👍

Ответить
@JhonTesfahun
@JhonTesfahun - 07.12.2022 09:55

nice work.

Ответить
@akhtarhussainshah7435
@akhtarhussainshah7435 - 15.11.2022 18:52

DAR b/w HV to LV, LV to G , HV to G

Ответить
@akhtarhussainshah7435
@akhtarhussainshah7435 - 15.11.2022 18:52

if DAR less the 1 it is dangerous need for maintenance if ration greater then 1 and less then 1.3 the check oil BDV mositure contents and C & DF test of winding if the ratio greater then 1.3 it is good

Ответить
@akhtarhussainshah7435
@akhtarhussainshah7435 - 15.11.2022 18:50

It is the ratio of reading taking after 15 or 30 seconds to reading taking after 60 seconds with same coonection as your video. Both readings are taken in one step. The purpose of this test is to ensure integrity of the winding insulation.

Ответить
@akhtarhussainshah7435
@akhtarhussainshah7435 - 15.11.2022 18:49

Dielectric Absorption Ratio (DAR) Test insulation test ruther then IR test

Ответить
@tyd3407
@tyd3407 - 08.08.2022 02:28

Major Farts 🤣

Ответить
@natural6086
@natural6086 - 16.07.2022 18:11

why did not you use guard terminal.

Ответить
@sunildevariya7965
@sunildevariya7965 - 21.06.2022 18:12

Tnx

Ответить
@kishorechandraprusty3351
@kishorechandraprusty3351 - 03.05.2022 07:31

What is the resistance value at a temperature of 40 degree celcius

Ответить
@shashanksahu2326
@shashanksahu2326 - 16.04.2022 09:36

It is really a very helpful video. It has cleared all my doubts. Thank u sir.

Ответить
@earnmoney2505
@earnmoney2505 - 23.02.2022 19:03

Thank you sir🙂 ,this is very helpful .

Ответить
@jaydoctor7824
@jaydoctor7824 - 30.01.2022 16:52

Thank you sir for your educational video.

Ответить
@judebarnes7595
@judebarnes7595 - 07.01.2022 11:19

Nice work - thank you for posting this video. In the calculations you compensate based on room temperature. Should you instead be compensating for transformer oil temperature.

Ответить
@nkvaishnav6395
@nkvaishnav6395 - 25.11.2021 19:52

Nice Explanation point to point...Will wait for next video.. Quality video..

Ответить
@kiwidevo1
@kiwidevo1 - 09.09.2021 11:15

What voltage are you setting the megger to for each test H-XG X-HG and HX-G ?

Ответить
@rangerrojo5047
@rangerrojo5047 - 14.08.2021 10:19

Nice work. What books do you suggest about this topic?

Ответить