How to Upgrade an Electric Meter to 200-Amp Service (Part 1) | This Old House

How to Upgrade an Electric Meter to 200-Amp Service (Part 1) | This Old House

This Old House

10 лет назад

3,031,310 Просмотров

Ссылки и html тэги не поддерживаются


Комментарии:

@danvincelett6049
@danvincelett6049 - 21.09.2024 02:43

How did he seal that hole he made in the house?!?

Ответить
@Btu555
@Btu555 - 17.09.2024 20:43

What's the advantage and disadvantage of PVC vs galvanized pipe? I don't see PVC pipe in Southern CA.

Ответить
@Só_lixo_aqui
@Só_lixo_aqui - 30.08.2024 05:39

Scabittron! Shouldn’t be doing the overhead service in PVC. Should be done in rigid metal conduit.

Ответить
@josephbennett7162
@josephbennett7162 - 20.08.2024 15:25

That bit coming out the other side of the wall😮!

Ответить
@jjosephbravata
@jjosephbravata - 17.08.2024 23:55

Why is there an expansion joint on the conduit on top of the meter can??? It doesn’t move? Is attached to the house.

Ответить
@samus1421
@samus1421 - 10.08.2024 23:48

Noalox

Ответить
@chuckschendel4671
@chuckschendel4671 - 10.08.2024 09:10

What happens when you have to replace your siding???

Ответить
@Icehso140
@Icehso140 - 06.08.2024 15:35

I know this vid is old but...Step 13...check NEC updates and realize that since 2020 the NEC requires an emergency disconnect at the meter for first responders. Of course, if this is CT, they are probably still 6 codes cycles behind. LOL

Ответить
@devenb1218
@devenb1218 - 30.07.2024 07:19

Just remember folks. Anything a licensed tradesman can do you can do for half price, and these days probably better if you put a little time and effort into it and getting the necessary knowledge

Ответить
@DrRussPhd
@DrRussPhd - 04.07.2024 03:36

Using aluminum wire for this?

Ответить
@seanstrickley3992
@seanstrickley3992 - 03.06.2024 05:00

Two things i see is no nolox for anticorrosion on the bare aluminum wires and when drilling inside hitting the 14/2 home run possibly shorting out that circuit. Other than that good stuff.

Ответить
@gregmiller-breetz3368
@gregmiller-breetz3368 - 23.05.2024 19:54

Wrong: ground rods do not provide an effective path to ground.

Ответить
@thisisyourtransmission
@thisisyourtransmission - 05.05.2024 00:47

Does anyone know why this electric box does not have a shut off latch at the box to disconnect the incoming power from the wires going into the house?

Ответить
@bigfish8280
@bigfish8280 - 28.04.2024 23:44

LOL 😂 where the heck do you guys live that you're able to push a ground rod in halfway and then finish it off with a mini sledgehammer?
Not a chance in hell where I'm from

Ответить
@allenzackery1639
@allenzackery1639 - 14.04.2024 21:28

Didn't show how you dealt with that big gaping hole that was enlarged behind the box...? And forget the cable company I would of gotten selfish on them and had them bring their own ground rod...!

Ответить
@williammontoute8968
@williammontoute8968 - 03.04.2024 16:04

It is always a better idea to install the supply cables and the load cables under the meter enclosure, this makes it almost impossible for water to enter the meter box. Entering at the top is not recommended because earth movements, storms, tornadoes, strong winds, hurricanes can cause small movement of the conduit, were water or moisture can enter. In addition, some metal expand or contract with temperature change.

Ответить
@davidater9
@davidater9 - 19.03.2024 05:24

Why did he leave the Cable ground hook up sooo far from the connection? It looks ugly. Could it have been made just below the level of the siding so it would look better?

Ответить
@wolfmanjacksaid
@wolfmanjacksaid - 13.03.2024 06:14

So glad that Maddox got a good honest job

Ответить
@williameisenberg1999
@williameisenberg1999 - 07.03.2024 20:53

Where’s the by pass arm in the Meter Socket ?

Ответить
@johndavies2949
@johndavies2949 - 05.03.2024 03:06

You have to use an insulated neutral wire as it is s current carrying conductor. The stranded alumnum wire is the grounding conductor.

Ответить
@1luvpizza-.-
@1luvpizza-.- - 25.02.2024 16:21

Why did he remove the meter like that?

Ответить
@willieclark2256
@willieclark2256 - 11.02.2024 23:35

"This should not be done by a homeowner"
Proceeds to explain literally every step in detail

Ответить
@HappyShappy.
@HappyShappy. - 11.02.2024 15:00

how much it cost from city for separate electric meter ?

Ответить
@beatboxbattleme4092
@beatboxbattleme4092 - 07.02.2024 06:33

How many times did the home owner hit his hand putting the ground rod??…

Ответить
@daveburgan
@daveburgan - 05.02.2024 07:07

What prevents moisture from entering the siding?

Ответить
@Mike_Greentea
@Mike_Greentea - 01.02.2024 12:37

“Thin Diesel”

Ответить
@johndavies2949
@johndavies2949 - 27.01.2024 08:25

So you bring in an insulated neutral from the riser then you change to an insulated neutral going into the building. That electrician Ron from New Jersey installs a bare neutral up his sebice entrance mast just like what comes in off the pole. The only problem with him doing that is the bare neutral is in contact eith the steel riser conduit and the neutral is a current carrying conductor and ad such you have two dissimilar metals in contact with one another which through electrolytic action the bare neutral will be eaten away. All current carrying conductors except the service drop from yhe pole should be insulated.

Ответить
@johndavies2949
@johndavies2949 - 27.01.2024 08:18

If this is sn upgrade like you ststrd ehy didn't you install a combo meter base main breaker for to provide overcurrent protection on the feeders going to the new panel and also provifed shut off from service drop for fire dept.

Ответить
@johndavies2949
@johndavies2949 - 27.01.2024 08:14

You don't need 2 ground rods as you have a cold water pipe as your primary grounding electrode. You fo need a supplementary grounding electrode but only 1 rod is required. You won't even need the supplemental ground rod if you can get to the rebar that is on the footing.

Ответить
@johndavies2949
@johndavies2949 - 27.01.2024 08:01

That service entrance cable have had an insulated neutral. What you have is 2 current carrying conductors and an equipment grounding conductor that is bare and you're using it as a neutral. You should have bought sevice entrance cable with 3 insulated conductors and the bare grounding conductor.

Ответить
@elijahhavemercy2719
@elijahhavemercy2719 - 09.01.2024 05:42

Whats the name of that bar u used to push the se cable into the terminal

Ответить
@prettybaby80
@prettybaby80 - 04.01.2024 22:30

How much does this cost ? I want to convert from gas to electric. Afraid I need to upgrade our electric panel

Ответить
@WiSeNhEiMeR-1369
@WiSeNhEiMeR-1369 - 04.01.2024 19:09

HOWdy T-O-H, ...
Thanks
COOP
the WiSeNhEiMeR from Richmond, INDIANA
...

Ответить
@ozzypr
@ozzypr - 31.12.2023 01:46

You miss a ground wire from the meter base to the MDP where all the circuit ground they come together on a bar separated from neutrals

Ответить
@josephabaddi8226
@josephabaddi8226 - 26.12.2023 23:06

What size is the new 200amp wire?

Ответить
@derickd2385
@derickd2385 - 23.12.2023 04:03

can I do it my myself?

Ответить
@kierenhudson6331
@kierenhudson6331 - 06.12.2023 04:19

In the uk that is called a club hammer not a sledge hammer 😂😂. Thats not a sledge hammer... THIS IS A SLEDGE HAMMER! BANG! 😅😂

Ответить
@johndavies2949
@johndavies2949 - 20.11.2023 05:14

How far away are you from first point of disconnect? Is it readily available for the fire department?

Ответить
@johndavies2949
@johndavies2949 - 20.11.2023 05:09

How come you don't use a meter base main breaker combo to facilitate disconnect if power to inside panel? On a replacement or upgrade isn't that required by the municipality and the fire marshal?

Ответить
@bills6946
@bills6946 - 19.11.2023 20:17

Waste of time. A service upgrade must be preformed by a licensed electrician only. The electric utility will not even speak to a homeowner to shut the old service drop or reconnect the new service drop. Only a licensed electrician can get them to come out

Ответить
@merllhagard6799
@merllhagard6799 - 27.10.2023 15:04

Lots of no no's with this one😂

Ответить
@beardedelephant3023
@beardedelephant3023 - 26.10.2023 23:00

What does something like this cost to do?

Ответить
@willpulera7303
@willpulera7303 - 13.10.2023 14:52

I did this to my house yesterday! Though not an electrician I'm a master carpenter and have experience building homes since I was in my late teens so I'm very comfortable doing my own work on my house and seeing how as I'm the homeowner I can pull the permits myself. There's nothing that a semi skilled mechanically inclined person can not do by themselves these days seeing how all information is in the palm of our hands including step by step instructions and video, then to top it off there's always the "experts" in the comment section that are so helpful and "friendly"!

Ответить
@sklee1644
@sklee1644 - 08.10.2023 08:40

Since you already have this grounded, do you still need to tie the neutral and ground bus bar at the main panel?

Ответить
@tecnisdaimondm.g9321
@tecnisdaimondm.g9321 - 01.10.2023 19:44

Excelente

Ответить
@brianohara5696
@brianohara5696 - 17.09.2023 22:18

Can’t believe you don’t use conduit pipe !!! You basically just ran a thick extension cord !!! How can you use all the cheapest materials . I would not put that junk on a trailer home 😂

Ответить
@exclusivesafar
@exclusivesafar - 14.09.2023 06:21

Very risky work
Good job 👍

Ответить
@ChemysteryKids
@ChemysteryKids - 14.09.2023 02:02

Hi I’m looking to setup a 200 amp panel 100 ft away (above ground, through the attic) I’m wondering which phase sub panel I need for that? Running 4-5 20 amp 110v lines and 2x 20-30 amp 220v lines. Also I’m wondering if this cable will be the correct cable for me to run box to box?:

4/0-4/0-4/0-4/0 Appaloosa Quadruplex Overhead Aluminum Conductor

Ответить
@dallas5374
@dallas5374 - 29.08.2023 03:35

Mickey Mouse electric.

Ответить