How to Test a Load Cell for Basic Functionality - Engineering Tips

How to Test a Load Cell for Basic Functionality - Engineering Tips

DwyerOmega

5 лет назад

107,357 Просмотров

Ссылки и html тэги не поддерживаются


Комментарии:

@nithiyashree4588
@nithiyashree4588 - 05.10.2023 11:21

Thank you for the explanation, while programming in psoc, are the four resistances at the bridge 350 ohm resistor or the values changes? What is the best way to amplify the milli-volt signals?

Ответить
@emma1328.
@emma1328. - 29.07.2023 16:08

Am a weighing bridge Engineer from Ghana that is the work I do I love this work

Ответить
@MST24
@MST24 - 12.07.2023 02:43

Great Job!

Ответить
@ahmedsharaf578
@ahmedsharaf578 - 08.07.2023 04:59

Excellent & simple explanation 👍

Ответить
@clementyaldo9203
@clementyaldo9203 - 11.06.2023 21:26

Hello im having a issue in my load cell where checking the strain gauge resistance between input and signal excitation the resistance is same but when giving voltage to the input and checking at the signal inputs in dc volt ,without applying load im having voltage in signal input as the given input. how can i rectify it??

Ответить
@debraperretta6610
@debraperretta6610 - 05.04.2023 19:34

Thank you so much for this video. I teach engineering and have a brand new (older model) Pitsco structure tester that was not working. They claimed it was the force sensor that was not working anymore and wanted to replace the entire tester for Almost 1K. Found the data sheet for tester and your video. Force tester is working fine...found out that the cable that they had running from the sensor to the onboard output/LCD screen was actually wired incorrectly! Circuit Board has connections SSEE and the sensor schematics have it SESE...It was wired SESE in the clip that connected it to the circuit board...so it was never able to read data! Wondering how many of these models were sold this way...this was not a refurbished structure tester.

Ответить
@mikefries2146
@mikefries2146 - 18.03.2023 06:58

Very good, thank you!

Ответить
@ratndeepthul8768
@ratndeepthul8768 - 15.02.2023 12:39

What if the resistance is ok but mv. Are going higher.?

Ответить
@bharanibharani8748
@bharanibharani8748 - 07.02.2023 17:19

Thank you it's helpes

Ответить
@brightonnyamakura7154
@brightonnyamakura7154 - 31.01.2023 12:23

Why do we use 10VDC as input voltage

Ответить
@aslanahadi5759
@aslanahadi5759 - 27.01.2023 01:50

Thank you. I want yo read the changes in voltage during a tensile test from our load cell. But our load cell is socketed to a (R232 i think) and is not bare wire. What should i do now?

Ответить
@maneki9neko
@maneki9neko - 15.12.2022 05:53

Nicely done. Everything you need to know in under 3 minutes.

Ответить
@pjcod4713
@pjcod4713 - 30.05.2022 05:27

Very clear explanation! Keep it up brother!!

Ответить
@charlemagnesantos61
@charlemagnesantos61 - 20.05.2022 06:46

Thanks alot. Learned alot.

Ответить
@nicholasakatwijuka3842
@nicholasakatwijuka3842 - 12.05.2022 16:33

This is awesome

Ответить
@brandonly27
@brandonly27 - 23.03.2022 04:05

Is the output linear with applied weight?

Ответить
@andresmanuelvilladiegovillalba
@andresmanuelvilladiegovillalba - 12.03.2022 15:52

Hi guys, how do I calibrate the cell in its factory parameters?

Ответить
@michaelrose3575
@michaelrose3575 - 09.12.2021 02:07

Great Video, would have been good to use a smaller load cell though. 25kgs or 50lbs then your mV would have changed ;)

Ответить
@tempemail5337
@tempemail5337 - 06.10.2021 00:29

Awesome, exactly what I was looking for. Thank You 😀

Ответить
@sinanartemis6176
@sinanartemis6176 - 05.09.2021 20:58

hello what about 6 wire loadcell test is it the same ?

Ответить
@sudhiracharya1234
@sudhiracharya1234 - 19.07.2021 09:37

Is working both tension as well?

Ответить
@johnnybuoy9551
@johnnybuoy9551 - 23.04.2021 18:18

Funny when Indians try their best to speak in White Accents lol

Ответить
@ProfessorOzone
@ProfessorOzone - 28.03.2021 20:48

I'm thinking about making corner weight scales for a car I'm building. Is it ok to leave the weight of the car on the load cells at each corner at all times? In other words, just build the car on the scales and whenever I add weight, turn on the scales and move the load around to try to balance things out, then turn them off when not in use, but NOT remove the load of the overall car?

Ответить
@PS-gv8ic
@PS-gv8ic - 23.03.2021 07:33

Loved the clip. If only all presenters had the English you have, with clear accents.

Ответить
@samuelampadu4346
@samuelampadu4346 - 18.02.2021 23:44

When I measure the load cell I get the reading in volts and not in millivolt/volt. Why?

Ответить
@minixone4048
@minixone4048 - 17.12.2020 03:59

Just like to ask if the normal resistance value is around 350ohm, and suddendly after using the it sometime, the scale becomes dead and upon measuring the resistance of the excitation and signal becomes double. Its reading is 850ohm on excitation and 780ohm on signal. Whats the cause of it that its value double? Is the load cell damage?

Ответить
@murugudubenarjeebabu1963
@murugudubenarjeebabu1963 - 16.10.2020 14:43

Hello sir could you please tell me how to calibrate weight machine which shows over load. If you tell me i will pay 150 ruppes through mobile sir. Please reply if you know or not.

Ответить
@maheshagowda4176
@maheshagowda4176 - 13.10.2020 04:55

How to callibrate weigh bridge machine

Ответить
@MK-kb1eh
@MK-kb1eh - 03.10.2020 21:49

Is there placed wheatstone bridge inside the load cell normally?

Ответить
@johnnybuoy9551
@johnnybuoy9551 - 28.09.2020 22:28

Looks like the lost brother of Hardik Pandya 😂😂

Ответить
@hedayatullahkhan3940
@hedayatullahkhan3940 - 12.09.2020 19:18

Sir nice information tell me if we have 8 load cell in weigh bridge and value is 2 mv/v how much should be value at out put.

Ответить
@VikashSingh-ff1jz
@VikashSingh-ff1jz - 08.09.2020 16:35

Please call me sir 7388818234

Ответить
@tamyboy1
@tamyboy1 - 08.08.2020 00:30

This helps a lot, thank you

Ответить
@ahmadindustries
@ahmadindustries - 29.07.2020 17:51

Dear Sir , I have an old model of instron 2511 Load Cell which is tension and Compression type , please help me which wire color is used for comression and which one for tension .

Ответить
@haditaimur5047
@haditaimur5047 - 16.07.2020 14:10

Hello Sir,
Have a nice day,
How can i stability test of a load cell ?
please help me.

Ответить
@dhrubajyotikumar8451
@dhrubajyotikumar8451 - 09.07.2020 18:38

Why in loadcell lead wire connected from site to panel .Which is 4 wire converted into 6 wire

Ответить
@nagarajuadapa4840
@nagarajuadapa4840 - 15.05.2020 17:04

How to install any panale bode
how to tack out put reading

Ответить
@nagarajuadapa4840
@nagarajuadapa4840 - 15.05.2020 17:02

Dear sir please tell me load cell electrical symbols

Ответить
@issamousa5518
@issamousa5518 - 23.02.2020 22:41

Hello sir
I got schenk weight scale 120 Ton
The problem is that after i don't use for 3 days i found mince reading like - 500 kg on the indactor screen

Ответить
@BrandonLopez-nk8ix
@BrandonLopez-nk8ix - 20.01.2020 07:52

What are those tips on your volt meter called ? Those are so cool !

Ответить
@masif1973
@masif1973 - 13.12.2019 21:22

great video

Ответить
@mikemcnabb3580
@mikemcnabb3580 - 11.12.2019 22:15

What if the input read 380 ohms and the output read 350ohms?

Ответить
@alamry3971
@alamry3971 - 24.11.2019 12:46

Thank you so much for this explanation.
I have same this type of load cell but it doesn't work. can I fix it or just replace it?

Ответить
@shaughnheyl9310
@shaughnheyl9310 - 20.11.2019 10:32

Great video ,thanks :) I'm struggling to find any info on what angle to mount a load cell in relation to the direction of force. In sim racing pedals they seem to be accepting an angular load rather than perpendicular to the load cell. Have a look at Heusinkveld Ultimate pedals for example. Thanks again :)

Ответить
@RS_83
@RS_83 - 18.06.2019 18:41

Thank you!

Ответить