Arc Fault Detection Device, Circuit Protection | Eaton

Arc Fault Detection Device, Circuit Protection | Eaton

Eaton

7 лет назад

79,431 Просмотров

Ссылки и html тэги не поддерживаются


Комментарии:

@tonnykolas
@tonnykolas - 21.12.2022 01:37

I worked with this idea 10 years back, and one of the detecting parameters was a specific arc generated radio frequency.

Ответить
@busway-electric
@busway-electric - 20.12.2022 20:36

Very interesting

Ответить
@udoumchh3985
@udoumchh3985 - 27.09.2022 16:34

Great video 👍 appreciate your sharing 🙏

Ответить
@md.tamimhassan1134
@md.tamimhassan1134 - 08.02.2022 20:45

How much price in Bangladesh?

Ответить
@MA-wf2ro
@MA-wf2ro - 16.12.2021 19:35

Thanks

Ответить
@tarassu
@tarassu - 31.05.2021 10:20

Interesting that Eaton device doesn't actually work. Has been tested by John Ward for example.

Ответить
@Passco666
@Passco666 - 02.02.2021 15:11

How it works with relay? Its react on switching?

Ответить
@021595756
@021595756 - 03.09.2020 19:14

WHAT COST OF AFDD

Ответить
@movax20h
@movax20h - 21.08.2020 23:00

Any chance for 5mA GFCIs? Also what is difference between type A and type AC sensitivity modes?

Ответить
@sandymcnair5298
@sandymcnair5298 - 23.07.2020 14:05

There was a lot of numbers quoted by Eaton at the beginning of the video with 4000 people killed, 70,000 in hospital, 126 Billion Euro and 25% of fires by an electrical failure. While sad to see these figure, I help feeling this is scaremongering. If Arc Fault Detection and Disconnection was introduced, how are these figures likely to be reduced?
Are there any investigative results that show the differences between the detection and disconnection of a parallel Arc Fault from both an AFDD vs RCBO?
A series Arc Fault would not be detected by conventional means and may require consideration of AFDD.
However, as these devices are costly and required double space within the DC, is user Education, good installation practices, periodic inspection and testing an alternative method of preventing arc faults. I feel that increasing the skill of installers and maintenance providers would be more beneficial than installing devices in place of workmanship?

Ответить
@bobcocampo
@bobcocampo - 21.05.2020 00:40

Do you have AFCI for 240 volts?

Ответить
@younismustafa5763
@younismustafa5763 - 06.05.2020 13:31

Great

Ответить
@kvn2124
@kvn2124 - 01.04.2020 21:28

What song?

Ответить
@Isurize
@Isurize - 10.02.2020 12:31

what is the standard of this device?

Ответить
@clubni8885
@clubni8885 - 20.11.2019 08:46

Thats sick background music, that piano is the real fire

Ответить
@NikolaosLedZeppelin
@NikolaosLedZeppelin - 31.08.2019 21:57

Is this immune to switching sparks or to ballast starter sparks etc?

Ответить
@bucklandnick
@bucklandnick - 08.11.2018 13:40

great video, with genuinely helpful animations , thank you

Ответить
@astritmexhuani4594
@astritmexhuani4594 - 26.07.2018 20:38

this device is for single phase can we used for three phase any device for this situtation

Ответить
@IncomeLifestyle360
@IncomeLifestyle360 - 10.09.2017 08:47

This is a good device.Can you please share the complete technical literature and where to buy?also how to buy online for Pakistan. Is delivery in other countries

Ответить