What is RS485 and How it's used in Industrial Control Systems?

What is RS485 and How it's used in Industrial Control Systems?

RealPars

5 лет назад

1,162,818 Просмотров

Ссылки и html тэги не поддерживаются


Комментарии:

Jesse Walter
Jesse Walter - 04.05.2023 14:04

Great video!

Ответить
Erik Zámečník
Erik Zámečník - 30.04.2023 11:11

This was very basic explanation.

Ответить
A K
A K - 22.04.2023 10:07

Max, how many devices you can connect in RS 485

Ответить
mohamad saeed
mohamad saeed - 26.03.2023 18:05

Great educational tutorial from RealPars, many thanks.

Ответить
Snozco Cram
Snozco Cram - 20.03.2023 21:37

My new residential heat pump uses rs 485 for thermostat and communication between the air handler and the compressor condenser. To bad Honeywell and others stick to the 5 wire c configuration…

Ответить
Habeb Sabri
Habeb Sabri - 28.01.2023 16:37

Thank you for the video.
I have a question, what is the maximum length that can be used for an ethernet cable?

Ответить
shahlal khan
shahlal khan - 25.01.2023 21:40

Nice tutorial regarding RS45 data cable in comparasion RS233

Ответить
frosty1
frosty1 - 18.01.2023 22:02

can you please with the wiring of 360 Visions Predator CCTV System? I have wired it through the Matrix Control Unit16/2 -and the joystick VKXM-0845-EU controller with RS485 cables, all that is coming out of the camera is a bunch of wires that have been chopped off. I have managed to identify all of them, but am unsure as how to wire the 4 wire twisted pairs, i.e., Red & Orange TX/ and Purple & Blue RX From the camera do they go to the matrix or the controller, and which pins on a RJ11 6 wire plug? any help would be very much appreciated as 360 vision diagrams only cater for the special power supply connector board, there seems to be no circuit diagrams available, I can supply pictures...

Ответить
Montes de Oca F.
Montes de Oca F. - 06.01.2023 09:35

I like this easy explanation

Ответить
công hậu trịnh
công hậu trịnh - 25.12.2022 14:30

nice video

Ответить
Signup Signup
Signup Signup - 23.12.2022 11:17

in your video for Rs-232, you indicated that the maximum cable length is 100 feet. while in this video is 50 feet. which one we should consider?

Ответить
Lutz Müller
Lutz Müller - 29.10.2022 13:02

Hello, I have a question about 485 communication.
Is it possible with a “D1 MINI WEMOS Pro 4M 16M” using “Tasmota” e.g., B. to control a “JUNTEK DPM8624 60V24A Programmable DC/DC Digital Adjustable Step Down Voltage Power Supply Buck Converter 485 Communication”?

Ответить
Ralfs HBK
Ralfs HBK - 12.10.2022 21:18

Where the limit of 32 devices comes from? I have electricity meters connected to rs485. It uses mbus and there is lot more devices than 32 and everything works. I'm confused.

Ответить
Mario porras
Mario porras - 14.09.2022 20:17

its a very good informative video. Just a little correction, when you say that an that an RS-485 network can only support 32
nodes. This is not true. Device manufacturers now sell 1/4 UL transceivers (DS1487) and even 1/8 UL parts (MAX1482).
Assuming each node presents 1/8 UL to the transmission line, an RS-485–compliant network may sport as many as 256 nodes (32 UL × 8 UL/node = 256 nodes).

Ответить
firos khan
firos khan - 21.08.2022 16:48

Which software using for create this video

Ответить
Bharat Thapa
Bharat Thapa - 10.08.2022 03:30

Hi RealPars, thanks for such an informative video. I have a question though. You showed in the video that the PLC and VFD are connected via RS-485. But what about the input and output terminals? Are input and output (i/o modules) needed in this system for control? My understanding was that we use the i/o module of the PLC to connect the VFD or any other type of field sensors, but it looks they are not needed once we connect the VFD with PLC via RS-485. Can you please clarify between the difference or relationship between input/outputs and communication standard? How these two work together in a system? Thanks a lot.

Ответить
felix sidabutar
felix sidabutar - 08.08.2022 12:27

nice 1

Ответить
Asif Nadeem
Asif Nadeem - 28.07.2022 22:42

Appreciated your explanation in a very simple way. Thanks

Ответить
Udit Buch
Udit Buch - 13.07.2022 13:07

Is RS-485 communication medium only used in Modbus communication protocol? Or is it used by other communication protocol in industries too?

Ответить
Funny clips
Funny clips - 22.05.2022 08:58

You just explained in a high level. Can you put a video about RS485 with deeper electrical specs and communication data format

Ответить
Karan KARAN JAMRHA AND JOHAR BHAI
Karan KARAN JAMRHA AND JOHAR BHAI - 20.05.2022 14:11

Thanks sir

Ответить
Airlangga Bhumintara Amitaba
Airlangga Bhumintara Amitaba - 09.04.2022 00:17

Thank you, your video helps me to understand RS 232 and RS 485

Ответить
Khader M. Mohammed
Khader M. Mohammed - 08.04.2022 07:13

What will be the gauge of the rs485 which allow 1200m

Ответить
angelito cortez
angelito cortez - 08.03.2022 00:54

Thanks a lot.and more power.

Ответить
حسان العصيمي
حسان العصيمي - 05.03.2022 18:30

thank you really I like that. 👍🏻

Ответить
VAISHNAVI KULKARNI
VAISHNAVI KULKARNI - 22.01.2022 09:03

thank you so much!

Ответить
Panca Sintesa
Panca Sintesa - 20.01.2022 11:46

Nice sharing

Ответить
Duke o Border Collie
Duke o Border Collie - 10.01.2022 14:43

Very good

Ответить
Dror Harari
Dror Harari - 08.01.2022 23:28

Thanks for the information. It left many basic questions unanswered (like what are the wiring and signals used and how are the basic protocols over RS-485 work).

Hoping to see a more in-depth video on those in future

Ответить
Dawood Iqbal Travel Vlogger
Dawood Iqbal Travel Vlogger - 07.01.2022 18:55

Could You Please make video on XY MOD2 humidity & Temperature sensors and its connection with input modules and PLC.

Ответить
shivanshu mishra
shivanshu mishra - 02.01.2022 10:17

Thanks

Ответить
Hari Haran
Hari Haran - 18.12.2021 21:28

Thanks for this video.could you make a video for all type of protocol communication (Rs485,IEC,modubus)

Ответить
Ivan Bratanov
Ivan Bratanov - 08.12.2021 22:44

I'm creating industrial automation projects. Yes, my brand is not Siemens, but those interfaces are still widely used despite the opinion that they are obsolete. That is not true. RS-232 is used for PC program upload/download/online mode in my projects. RS-485 (together with Ethernet) is used as main interface between the devices. On the other hand equipment which supports EtherCAT, CANopen and other modern time interfaces is more expensive. In most cases fast interfaces are not needed, so RS-485 meets the requirements.

Ответить
Dave of Yorkshire
Dave of Yorkshire - 28.11.2021 01:20

RS232 maybe older but that doesn't make it better or faster... RS485 can run up to modern standards of 250k baud+ and is fault tolerant and self correcting, which is why it's an industrial standard used on oil platforms (before optical) and nuclear power plants... Used in both monitoring and control scenarios.

Ответить
brahim abdelsadek
brahim abdelsadek - 23.11.2021 01:35

Thanks this time and every time.please keep doing the right things👍👍👍👍👍

Ответить
christy usa Eris
christy usa Eris - 11.11.2021 22:06

Jesus, 700k views for a geek as fck video

Ответить
Marco L
Marco L - 14.10.2021 21:04

So it is correct say that Profibus is based on Rs485 protocol ?
Thanks a lot for the video

Ответить
Jason Woodrow
Jason Woodrow - 13.10.2021 16:22

Is RS-485 a protocol or an electrical standard? When I use RS-485 in the field, it is usually either security panels or PTZ camera controls, and each of those use different proprietary communications protocols OVER an RS-485 connection. One example is Honeywell panels that use RS-485 and their own communication protocol and so require Honeywell gizmos to interpret their protocol and translate to RS-232 which is then converted to Ethernet to talk to a server and database. It is akin to speaking the same language over a telephone, but someone who doesn't speak that language needs a translator. Another example is a PTZ camera that has an RS-485 2-conductor cable back to a PTZ controller. Just having the cable connection is not enough, they both need to be set to a particular communication protocol (speak the same language over the line) such as Pelco-D, Samsung, Vicon, as well as having the same baud rate.

Ответить
Azzter Eris
Azzter Eris - 02.10.2021 10:02

thanks, my right ear got it!

Ответить
Arthur mordan
Arthur mordan - 30.09.2021 22:03

You made a Great job in this channel , thanks you to much

Ответить
Jason
Jason - 27.08.2021 16:55

Nice video, btw what is the differences between using RS485 vs analog input output for communication between PLC and VFD? THX

Ответить
Sergio Jimenez
Sergio Jimenez - 18.08.2021 10:12

Nice video! Very didactic! 💯 I think the only missing thing was to mention the 2-wire o 3-wire type of RS-485 and the terminator resistors or voltage bias at each end of the network

Ответить
Ogatech System
Ogatech System - 25.06.2021 05:25

I want to convert from RS232 to RS485 (My HMI and PLS ports are RS232) and I am using an Optical Fiber extender with RS85.

Please which of the pins (from 1-9) do I use as my positive and negative on the serial port pin?

Ответить
Javier Costa Emil Kazinjsky
Javier Costa Emil Kazinjsky - 29.05.2021 21:15

nice video!. Thanks for teaching us all the time!

Ответить
Mr石
Mr石 - 25.04.2021 06:05

A communication bus that is easier to use than RS-485. The bus can provide power 20A

Ответить
Prashant Verma
Prashant Verma - 13.04.2021 18:06

how to check Furness temperature by Temperature indicator & HMI?

Ответить