Комментарии:
Very clear. Thank you!
ОтветитьThis I like at the UK regulations: The RCCB/RCBO use only one space place. In Germany all 2pol (L+N) RCCB/RCBO are two space wide, mean need special power bar with L+N. Here use mostly L1+L2+L3+L1 aso. or same L as in UK. We say RCD to a RCCB here. A normal device is a MCB.
Ответитьvery very clear. thanks a lot
Ответитьgreat video tutorial,very informative.
thank you for sharing your knowledge.❤️
Great clarity
ОтветитьHello sir,
Should the outdoor service switch be greater or smaller than the main breaker in the consumer unit?
I'll be so grateful if you would send me back.
Thank you,
Khalid
Very good explanation indeed.Thank you sir !
Ответитьis its operation based on Kirchhoff Current Law?
ОтветитьThank you eng joe 4 your great information, really needed to add it to my knowledge.👍😇
Best wishes to u .
Khalid RAC tech.
Thanks
ОтветитьI just started a new job doing panel building. Your videos help me a lot.
ОтветитьWhere is the FE wire (white) of the RCBO?
ОтветитьWhat about earth leakage circuit breaker? Very confusing.
ОтветитьClearly and concisely explained. Thank you Joe.
ОтветитьHi joe, do you have any idea why BS7671 forbids installing RCD's in a TNC system? I am aware that this is not a perfect protection, but in old buildings which don't have any earthing system, the presence of an RCD would be better than not using it.
ОтветитьThese rcbo devices create extremely high levels of dirty electricity, in turn creates fibromyalgia increases to the suicide rate, hopefully these devices are phased out in the future
ОтветитьHow to identify a rcbo. Please someone explain
ОтветитьWhat link below??
ОтветитьAs a student surveyor this was excellent watch. Thanks
ОтветитьWhy havent the engish speaking people a proper name for things??We call them the Group breaker(translated off course) and Alamat.And the box with the group breakers a group breakers box!Almost ever situated right after the frontdoor in a special cupboard with a normal door.Gas and water will also be there.Heated and cold.And of course the Earhtleak breaker.
ОтветитьSame electrical systems different county different ways of doing it 🇺🇸 🇬🇧 very interesting 🤔
ОтветитьWhere’s the link?
Ответитьwell explained Joe.Thanks
ОтветитьIs it possible to use one RCD(or RCBO) with one AFDD to secure multiple circuits (6 for example) that are protected with MCBs? Im bit confused with installing AFDD, because its expensive to use on every circuit, but if can use 2 or 3 per board instead of 15 that would be great.. Eu-installation
ОтветитьNo the front of them it say test regularly, sparks installs, tests, and fills out the forms that’s the last time that ever gets looked at until something goes wrong, real life. 😃
ОтветитьGreat video Joe 👍 thanks
ОтветитьNice one .. have seen only the rcd fitted to some circuits 😯😯
ОтветитьHey - hobbyist here with a good understanding of electricity. Will soon be undertaking a home renovation which will include a (professionally installed) new consumer unit etc. Looking at RCBO but noticed that most are single pole rather than dual (like an RCCD) - i.e. an earth to neutral short would trigger the RCBO disconnecting phase but not neutral. Isn't this less than ideal?
ОтветитьWhere is this information that you said “ it’s down below for us to click “ ?
I don’t see any !
Davis Malik
Impact Driver
ОтветитьNice 👌
ОтветитьThe transformer winding polarity on that drawing is wrong
Ответить