If Span is 8 Meters b/w Two Columns Than what should be the depth of Beam?How to Find Depth of Beam?

If Span is 8 Meters b/w Two Columns Than what should be the depth of Beam?How to Find Depth of Beam?

Civil Engineers

4 года назад

98,994 Просмотров

Ссылки и html тэги не поддерживаются


Комментарии:

@merchanthandson5271
@merchanthandson5271 - 09.09.2023 09:30

Please tell where you are getting formula? Because i seen a formula...
Depth of beam=L/10 ; Width of beam=L/12. For a 2 floor building but the L should not be greater than 6meters.

Ответить
@praveenbhardwajswami1231
@praveenbhardwajswami1231 - 22.08.2023 20:46

Hindi mai banao iss video ko

Ответить
@interiordesign4650
@interiordesign4650 - 23.07.2023 05:43

His value is bottom size or including ( Lenter ) RCC slap

Ответить
@sso-m-ai
@sso-m-ai - 16.02.2023 04:09

I am looking for someone who can provide full report for Steel Structure - 700 sq Feet G + 3 Storey

Ответить
@fayazfaizan5070
@fayazfaizan5070 - 14.02.2023 09:43

Does it apply in drop beam also r only great beam

Ответить
@mib9550
@mib9550 - 24.11.2022 07:27

When do you use D=L/16? You have used this in previous videos.

Ответить
@arfatullah5632
@arfatullah5632 - 02.09.2022 08:48

On which basis you say that..? What types of code you are following..?? Also mention the code.. It is just only time wasting

Ответить
@noliwenceslao2996
@noliwenceslao2996 - 04.08.2022 03:03

Good morning Engr. Is it possible to construct a beam, 12 meters in length between two columns using I-beam for a two storey house?

Ответить
@diamondbracelette
@diamondbracelette - 07.07.2022 20:06

Using what material?

Ответить
@bhabajitbarman653
@bhabajitbarman653 - 07.04.2022 07:12

if is code is not safe for 8m span.. who the hell designed this is code

Ответить
@FoodforThought-Plus
@FoodforThought-Plus - 04.04.2022 01:15

as a general rule divide the span by 15

Ответить
@saleemqazi6242
@saleemqazi6242 - 11.03.2022 17:44

Dear admin I thing you have not enough capability to answered all the comments give below 👇👇👇👇

Ответить
@apurbadatta2485
@apurbadatta2485 - 31.01.2022 20:55

Dir, you said the beam depth is 8000/20= 400mm,, my question is ,,
Is this 400 mm beam including with slab thickness ?? or it is excluding slab thickness...

Ответить
@apurbadatta2485
@apurbadatta2485 - 31.01.2022 20:43

Sir , this 600 mm beam that you said,, is it including slab or excluding slab ??

Ответить
@qasimalibadi1302
@qasimalibadi1302 - 15.01.2022 09:42

You deserve super like & admire

Ответить
@rozayhomesdesign301
@rozayhomesdesign301 - 07.01.2022 07:14

Please what do you mean by depth of beam.

Ответить
@pong3753
@pong3753 - 20.11.2021 17:44

Bobo

Ответить
@mohanakrishnan1150
@mohanakrishnan1150 - 01.11.2021 10:27

Good👍

Ответить
@mmmmmmmmmmmm672
@mmmmmmmmmmmm672 - 20.10.2021 14:28

A good soil condition..I have to built a 4 story house...my architect designed 20feet beam ...our constructor planning to use 20mm 4 steel bars...also colum with 16mm 4 steel bars and 10mm 4 steel bars..is it safe..

Ответить
@mithunprince9501
@mithunprince9501 - 15.10.2021 15:14

For 10 meter span ,what will be the depth and width...??? Is it possible to make beam for 10 meter length ( simply supported)....???

Ответить
@stanzingurmat3824
@stanzingurmat3824 - 08.10.2021 07:50

If d distance between two columns 6mtr
What should d columns size is

Ответить
@IbrahimKhan-gd1df
@IbrahimKhan-gd1df - 07.07.2021 09:56

I need sami sir's mail il, plz

Ответить
@saeddnafee5820
@saeddnafee5820 - 28.06.2021 16:55

Salam , can we mix between column for example en the center diffrent from the other.

Ответить
@RanjithKumar-di6tk
@RanjithKumar-di6tk - 09.04.2021 19:12

Fixed beam?

Ответить
@udayam77
@udayam77 - 29.03.2021 21:03

I was wondering if you could do a video on depth of continuous beam. Thanks.

Ответить
@SANJADHAV475
@SANJADHAV475 - 14.03.2021 16:08

अगर ग्राउंड फ्लोअर के हॉल की साईज 21 बाय 10 हे तो कॉलम और बीम की साइज क्या होनी चाहिये

Ответить
@sa-xc4lj
@sa-xc4lj - 11.01.2021 23:03

hello sir If my span is 10 meters between two columns can I use trussed beams ?

Ответить
@hoangkybactien7207
@hoangkybactien7207 - 04.01.2021 07:32

L/20 is for steel beams such as I/H beams. For steel-reinforced concrete beams, it should be L/12 or L/15 as minimum. I am not a civil engineer, but that is what I've come up.

Ответить
@gangannaar9283
@gangannaar9283 - 17.12.2020 04:44

This my case domestic building kindly send your mobile number 🙏

Ответить
@jerrychibunna1892
@jerrychibunna1892 - 20.11.2020 02:58

My question is for span of 7.6m in your earlier tutorial you said for span of 7.6m beam btw two columns the column size will be 400mm x 400mm and that the depth of beam is 7.6m/16. How come in this tutorial you said the depth of beam will be span/20 instead of span over 16. And if 7.6m span the column size is 400 x 400 I am thinking 8m will be 421mm x421mm taking reference from your previous lecture on 7.6m span

Ответить
@hafizadnan592
@hafizadnan592 - 10.11.2020 18:17

Asalamualaikum brother..
It is Hafiz Adnan from Kashmir (Jammu and Kashmir)
Hope u will be doing fine
Firstly u used L/d formula for calculation of effective depth of beam
Then u said I can bet that it will fail in very first trial...
Then how can i myself decide

Ответить
@mcan-piano4718
@mcan-piano4718 - 10.10.2020 18:13

I am confused cuz in other codes it says the depth of beam should be for simply supported SPAN/12 instead of SPAN/20

Ответить
@isaacfrimpong92
@isaacfrimpong92 - 27.09.2020 22:17

thanks for the support and education

Ответить
@ayoubenaciri
@ayoubenaciri - 23.07.2020 21:25

Thank you Sir so much 🙏🙏

Ответить
@m.v.b605
@m.v.b605 - 06.07.2020 03:50

Hi bro make a video on 30 foot span for commercial building
With column size and etc

Ответить
@dilshikadilshi8103
@dilshikadilshi8103 - 05.07.2020 17:36

Super... you are my favourite teacher sir...

Ответить
@civilengineeringtolifeengi3333
@civilengineeringtolifeengi3333 - 05.07.2020 17:17

This is very basic but helpful video ...Good Explanation .

Ответить
@civilengineeringtolifeengi3333
@civilengineeringtolifeengi3333 - 05.07.2020 17:16

HELLO FRIENDS & ENGINEERS , IT IS A GOOD AND HELPFUL VIDEO .

Ответить
@josephoyek6574
@josephoyek6574 - 05.07.2020 14:32

Is this formula used in the actual job setting? You said the final depth will still depend on the loading carried by the beam. Won't this require software like etabs or staad?

Ответить
@nafeedhnaina5064
@nafeedhnaina5064 - 05.07.2020 10:36

What about the steel size, number of rods, cover & stirrups Spacing & dia

Ответить
@md.mizanurrahmanaru3128
@md.mizanurrahmanaru3128 - 05.07.2020 10:21

♥ U Sir,,,,, From Bangladesh,,

Ответить
@Boss-gk8kc
@Boss-gk8kc - 05.07.2020 10:19

How about the width of the beam? You only discussed depth

Ответить
@Boss-gk8kc
@Boss-gk8kc - 05.07.2020 10:18

How about length of beam is 8m but existing column is flush in the wall size 20*60. Is the column ok?

Ответить
@mubashirbashir8214
@mubashirbashir8214 - 05.07.2020 10:06

Assalamualaikum sir can u teach us the surveying also please

Ответить
@avdheshbodhidharma8790
@avdheshbodhidharma8790 - 05.07.2020 09:00

hello
sir
sir kiya aap autocad complete tutorials series bana shakte hooo please
thank you

Ответить
@ramakantsalam6132
@ramakantsalam6132 - 05.07.2020 08:28

Why it is not 400 mm depth according to d formula......

Ответить
@manisharma1831
@manisharma1831 - 05.07.2020 08:24

sir can you please explain singley and doubley reinforced beam.. and also axial and biaxial column...

Ответить
@sushilrajput3047
@sushilrajput3047 - 05.07.2020 08:06

Sir issme modification factor use
nahi hoga kya

Ответить